104 | TEMPERATURE CONTROLLERS |
Summary |
| << Previous | |||
| Next >> |
| CHOOSING A CONTROLLER |
| The VULCANIC range of controllers covers the great majority of industry requirements. Following steps will help you to define the right controller. | 1) define the desired control precision: if ± 5°C, choose an ‘ON/OFF’ controller ; for greater precision, consider a ‘PID’ appliance. 2) Know what kind of temperature input is used : PT100 - Thermocouple - Current – Voltage. 3) Know what kind of power supply device is to be driven, so as to choose the type of control output (usually called ‘Output P/N.1): - for a contactor, choose a controller with a ‘relay’ output - for a power unit, choose a controller with a ”numeric” output - for a device with an analogic input (eg : motorised valve) choose a controller with an ”Analogic” output. 4) Know what use will be made of the auxiliary outputs (usually called ‘Output N°2 and N°3’) : choose a ”Relay” output to drive an alarm, ”Current or Voltage” for a measurement repeater, and/or “Cold” output 2 to drive an ON/OFF valve for a cooling system. |
| 48x48 ON/OFF CONTROLLERS WITH 3-DIGIT DISPLAY |
|
| 48x48 AUTOTUNE CONFIGURABLE PID TEMPERATURE CONTROLLERS |
| P/N | Old | Input | Range | Output | Output | Output |
| P/N | Temp. (°C) | Regulation | 2 | 3 | ||
| 30656-01 | 30655-01 | PT 100 | -50/+350 | Relay | Alarm | - |
| 30656-02 | 30655-02 | PT 100 | -50/+350 | Logic | Alarm | - |
| 30656-03 | 30655-03 | PT 100 | -50/+350 | Relay | Cold relay | Alarm |
| 30656-04 | 30655-04 | PT 100 | -50/+350 | Logic | Cold relay | Alarm |
| 30656-13 | 30655-13 | TC/J | 0/+450 | Relay | Alarm | - |
| 30656-14 | 30655-14 | TC/J | 0/+450 | Relay | Cold relay | Alarm |
| 30656-15 | 30655-15 | TC/J | 0/+450 | Logic | Alarm | - |
| 30656-16 | 30655-16 | TC/J | 0/+450 | Logic | Cold relay | Alarm |
| 30656-21 | 30655-21 | TC/K | 0/+1200 | Relay | Alarm | - |
| 30656-23 | 30655-23 | TC/K | 0/+1200 | Logic | Alarm | - |
| 30656-05 | - | PT100 | -50/+350 | Analogic | Alarm | - |
| 30656-17 | - | TC/J | 0/+450 | Analogic | Alarm | - |
| 30656-24 | - | TC/K | 0/+1200 | Analogic | Alarm | - |
| Microcards for reconfiguring the appliance ( they are used for PID controllers type 30656 or 30881 ) | |
| 30656-92 | SPDT relay and PWM circuit board for main output |
| 30656-96 | Analog circuit board for main output ( voltage or current ) |
| 30656-90 | SPDT relay circuit board for output 2 and 3 |
| 30656-91 | Analog circuit board for output 2 or 3 ( voltage or current ) |
| 30656-99 | PWM circuit board for output 2 or 3 |
| 30656-93 | RS 485 circuit board, MODBUS or ASCII for option A |
| 30656-97 | Carte consigne analogique 0/5 VDC ou 0/10 VDC ou 2/10 VDC ou 0/20mA ou 4/20mA, pour option A |
| 30656-95 | Setpoint selection by single pole contact for option A |
| 30656-98 | Power supply 24 VDC / 20 mA for cooled output |
| 48x96 AUTOTUNE CONFIGURABLE PID TEMPERATURE CONTROLLERS |
| P/N | Input | Range | Output | Output | Output |
| Temp. (°C) | regulation | 2 | 3 | ||
| 30881-01 | PT 100 | -50/+350 | Relay | Alarm | - |
| 30881-02 | PT 100 | -50/+350 | Logic | Alarm | - |
| 30881-03 | PT 100 | -50/+350 | Relay | Cold relay | Alarm |
| 30881-04 | PT 100 | -50/+350 | Logic | Cold relay | Alarm |
| 30881-05 | PT 100 | -50/+350 | Analogic | Alarm | - |
| 30881-13 | TC/J | 0/+450 | Relay | Alarm | - |
| 30881-14 | TC/J | 0/+450 | Relay | Cold relay | Alarm |
| 30881-15 | TC/J | 0/+450 | Logic | Alarm | - |
| 30881-16 | TC/J | 0/+450 | Logic | Cold relay | Alarm |
| 30881-17 | TC/J | 0/+450 | Analogic | Alarm | - |
| 30881-21 | TC/K | 0/+1200 | Relay | Alarm | - |
| 30881-23 | TC/K | 0/+1200 | Logic | Alarm | - |
| 30881-24 | TC/K | 0/+1200 | Analogic | Alarm | - |
| Microcards for reconfiguring the appliance | |
| 30881-90 | Circuit board for analogic remote setpoint : 0/5 VDC, 0/10 VDC, 2/10 VDC or 0/ 20 mA or 4/ 20 mA for option B, with local / remote switching by contact out of potential |