Pdf version
Logo Vulcanic 63

VULSTAR ® CARTRIDGES

Summary
 << Previous
Next >>
APPLICATIONS
Vulstar® cartridges are used to heat metal like moulds, dies, plates and bolts or liquid. They can be provided with a thermocouple .
Cartouches chauffantes pour le chauffage de pièces métalliques
VULSTAR® cartridge with thermocouple
Cartouches chauffantes Vulstar équipées d'un thermocouple
VULSTAR® must be inserted in a drilling with an H7 allowance, pre-lubricated with an anti-corrosion product to facilitate installation and removal.
Where possible, this drilling must be extended by a hole through the other side for insertion of an extractor. Length L must be fully in contact with the medium to be heated. The high heat flow of VULSTAR® cartridges requires efficient temperature control with a probe (usually a J- or K-type thermocouple) installed close to the heating section.
Mould
Moules à empreintes équipés de cartouches chauffantes Vulstar
Hotplates
Plateaux chauffants équipés de cartouches chauffantes Vulstar
shaping dies
Couteaux de formage équipés de cartouches chauffantes Vulstar
Heat sealing
Outils de soudage équipés de cartouches chauffantes Vulstar
Marking appliances
Appareils de marquage équipés de cartouches chauffantes Vulstar
Band heaters
Manchons chauffants équipés de cartouches chauffantes Vulstar
Liquid heating
Cartouches chauffantes Vulstar pour le chauffage de liquides
Bold heater
Chauffe-boulons fabriqués à partir de cartouches chauffantes Vulstar
Supply voltage up to 450 V 1P or 3P.
Load up to 40 W/cm2.
Length from 25 mm to 2500 mm depending on diameter.
Diameter from 6,35 mm (1/4”) up to 31,8 mm (2” 1/4).
Different types of connection to fit with the ambient temperature.

Cartouches chauffantes Vulstar pour le chauffage de pièces métalliques ou le chaufage de liquides
Compliance with VDE standards.
Connecting leads Standard length S = 350mm.
2 flexible braided nickel leads, silicone-coated glass fibre insulation (max. temperature 350°C).
Cartouches chauffantes Vulstar avec conducteurs de connexion en tresse nickel isolée  soie de verre
2 flexible braided nickel leads, kapton insulation (max. temperature 400°C).
Cartouches chauffantes Vulstar avec conducteurs de connexion en tresse nickel isolée  kapton
Longueur standard S = 350 mm
Lc = Longueur chauffante
Protection of connecting leads

 

2 flexible NSV or KPT leads, mechanically protected by a flexible metal sheath attached axially.
Cartouches chauffantes Vulstar avec conducteurs de connexion protégés mécaniquement
2 flexible NSV or KPT leads, mechanically protected by a flexible metal sheath attached radially..
Cartouches chauffantes Vulstar avec conducteurs de connexion protégés mécaniquement
2 flexible braided nickel leads, thermally protected by ceramic beads (max. temperature 450°C).
Cartouches chauffantes Vulstar avec conducteurs de connexion protégés thermiquement
One 3-core cable, encased in resin to ensure a watertight connection.
Cartouches chauffantes Vulstar avec conducteurs de connexion étanches
Fitting devices
Reversed plug
Cartouches chauffantes équipées d'un bouchon de fixation inversé
Plug
Cartouches chauffantes équipées d'un bouchon de fixation
Fixed stop
Cartouches chauffantes équipées d'une patte de fixation
Different types of seals
WP+ (WaterProof Plus): For connection temperature up to 160°C.
MT (Medium Temperature): Sealed for connection temperature up to 220°C in low pollution environments with low humidity and no sudden temperature changes.
HT (High Temperature): Most frequently used. Non-waterproof seal for connection temperature up to 350°C, in a humidity-free atmosphere